AI-driven IC design · Hardware-security research
BBICS laser current sensors.
Classic BBICS and S2 sensing principles on two monitored N-wells of one 16-flop register.
Two sensors. One monitored register.
A test structure for laser fault-injection research. A 16-flop shift register is the target, and its PMOS transistors sit in two separate N-wells: flops 1 to 8 in one, flops 9 to 16 in the other. Each well reaches the supply only through a bulk built-in current sensor (BBICS), which watches the current a laser shot drives out of the well and sets a flag when it is large enough. The two wells carry two different sensors, a classic BBICS and a second design, S2, so that both can be compared under the same laser on the same chip. The flags are latched and read through the chip's cell-test pads, together with the register bits, so that one measurement shows both whether a sensor saw the shot and whether a flop was upset.
- Technology
- 65 nm CMOS
- Monitored register
- 16 flip-flops
- Human hands-on time
- < 1 h
Human-directed AI design
Human hands-on time: less than 1 h. AI agents did the architecture study, the design, the layout and the verification, under the direction of Raphael Viera. The two sensors watch identical 8-flop halves of the same register, each in its own laser zone, so that the silicon compares the two sensing principles under the same laser. The register, its flops and both sensors are custom transistor-level circuits, which keeps the two monitored wells, the layout-versus-schematic check and the strike simulations under our control.
How the two sensors work

Classic BBICS (flops 1 to 8). The well reaches the supply through a minimum-width PMOS used as a resistor. A sensing PMOS has its gate on the well and drives a latch whose hold device is weak. A laser shot pulls the well down; once the well sits about one threshold voltage below the supply, the sensing PMOS overpowers the hold and the latch flips. The access PMOS sets how much well current that takes, the hold strength how fast the latch tips. There is no bias current.
S2 (flops 9 to 16). The well reaches the supply through a 2 kΩ resistor and is AC-coupled by a 50 fF capacitor to the gate of a sensing PMOS that is already conducting a small bias current. A sink mirrored from the same bias takes a fixed multiple of that current, so the comparator node flips the latch when a fast well dip of about 0.1 V raises the sensing current past it. The threshold is set by a current ratio rather than by a threshold voltage. Once the flag is set, a clamp transistor re-ties the well to the supply. Slow changes of the well, such as heating or supply drift, are attenuated by the coupling capacitor.
Readout. Both flags are latched until the next trigger pulse, which also starts a capture frame. The output into the cell-test XOR chain flips as soon as either flag sets. When the register is clocked afterwards, the clock-high slots carry the register bits and the first two clock-low slots carry the S2 flag and then the classic BBICS flag, so the two flags never share a slot and never cancel. The chip reset clears the register.
Layout and laser zones

Area (drawn macro outline): BBICS laser current sensors 56.935 × 112.0 µm = 6,377 µm², most of it the two laser zones. The classic BBICS takes one placement row of 37.1 µm² (sensor, latch and two flag buffers); S2 takes three rows (209.1 µm²) and its coupling capacitor (56.8 µm²).
Key results and simulation basis
Post-layout simulation with extracted parasitics. 65 nm bulk CMOS, the released layout. Corners: tt typical, ss / ff slow / fast, sf / fs mixed; temperatures 0 to 85 °C; supply 1.14 to 1.26 V. Strikes are currents injected into the well (no laser-power figure is used); a threshold is the smallest strike on the simulation grid that sets the flag.
| Measure | Classic BBICS | S2 | Specification | Basis |
|---|---|---|---|---|
| Detection threshold, 60-ps prompt (charge into the well), typical | 84 fC | 80 fC | ≤ 100 fC | post-layout, tt, 27 °C, 1.20 V; the RC-extraction check gives the same values |
| Detection threshold, 60-ps prompt, over the corners | 56–108 fC | 64–100 fC | ≤ 100 fC | post-layout, 31 points: 5 corners × 0 / 27 / 85 °C × 1.14 / 1.26 V, and tt, 27 °C, 1.20 V |
| Detection threshold, 5-ns pulse (current into the well): typical; over the corners | 25 µA; 20–30 µA | 50 µA; 40–70 µA | ≤ 100 µA | post-layout, 31 points |
| Prompt threshold under mismatch, 27 °C, 200 runs: largest | 88 fC (all runs within one 4-fC step) | 76 fC (mean 68.6, σ 2.9 fC) | ≤ 100 fC | post-layout Monte Carlo, local mismatch |
| 5-ns threshold under mismatch, 27 °C, 200 runs: largest | 25 µA (all runs within one 5-µA step) | 60 µA (mean 46.7, σ 4.4 µA) | ≤ 100 µA | post-layout Monte Carlo |
| Strike to the flag latch, prompt at twice the threshold | 92 ps typical; 78–117 ps | 156 ps typical; 136–191 ps | information | post-layout, 31 points |
| Strike to the macro output (into the cell-test chain), same strikes | 0.48 ns typical; 0.37–0.68 ns | 0.65 ns typical; 0.50–0.91 ns | ≤ 0.5 ns target; ≤ 1 ns accepted | post-layout, 31 points |
| False flags with the register clocked (50 / 100 MHz, slow edges) and on the chip's supply-noise traces | 0 in 81 runs | 0 in 81 runs | 0 | post-layout, 37 clocked and 44 supply-noise runs over the corners |
| Detection level over the largest disturbance at the sensor input | 4.5× (268 mV over 59.1 mV) | 3.7× (55 mV over 15.1 mV) | ≥ 3 | post-layout; detection level from the corners and the Monte Carlo |
| Static supply current of the whole macro, clock held still | no bias branch | 1.08 µA typical; 0.39–4.58 µA (whole macro) | ≤ 5 µA | post-layout, 31 points |
| Clock-to-output change of the monitored flops, against wells tied to the supply | 0.43 ps at most | (same register) | ≤ 2 ps | post-layout, 3 points |
| Flag clear from the trigger edge: pulse width; pulse over by | 458 ps or more; 1.21 ns at most | (both flags) | ≥ 200 ps; < 1.5 ns | post-layout, 31 points, at the macro input |
| Gate-oxide overvoltage (above 1.32 V for 0.1 ns or more), normal operation | 0 events | 0 events | 0 events | post-layout, 7 corners at 1.26 V: supply ramp, clock burst, reset and trigger pulses, supply step |
Additional characterization results and extraction scope
Post-layout characterization of the signed-off layout in 65 nm CMOS: tt, 27 °C, 1.20 V unless a caption says otherwise. The sweeps over corners, temperature and supply and the Monte Carlo reuse the sign-off simulations (capacitance-only extraction); the waveforms are simulations with full RC extraction. Strikes are currents injected into the monitored well: a 60-ps prompt (double exponential, 15 / 60 ps) or a 5-ns pulse; no laser-power figure is used. Post-layout simulation with extracted parasitics.
| Quantity | Classic BBICS | S2 | Basis |
|---|---|---|---|
| Prompt threshold with RC extraction, tt | 84 fC | 80 fC | post-layout, RC extraction |
| 5-ns pulse: strike to the flag latch at twice the threshold | 2.39 ns typical; 1.94–2.60 ns | 1.48 ns typical; 1.13–1.81 ns | post-layout, 31 points |
| Well dip at the sensor input that sets the flag, tt (prompt / 5-ns pulse) | 0.46–0.48 V / 0.37–0.47 V | 0.25–0.31 V / 0.08–0.10 V | post-layout, grid bracket (largest dip without a flag to smallest with one) |
| Prompt threshold under mismatch at 0 / 85 °C (100 runs each): largest | 92 / 76 fC | 72 / 88 fC | post-layout Monte Carlo, one seed per set |
| Largest disturbance at the sensor input: clocking only / with supply noise | 15.6 / 59.1 mV | 12.1 / 15.1 mV | post-layout, 81 runs |
| Supply current with the register clocked at 50 MHz | 29.5 µA = 35.4 µW (whole macro) | post-layout, RC extraction, tt | |
| Flags cleared after the trigger edge, at most | 476 ps | 435 ps | post-layout, 31 points |
| Well dip during a 100-ns shot of 50 µA to 2 mA; time more than 0.5 V below the supply | 0.59–0.86 V; the whole shot | 0.09–0.83 V; at most 0.37 ns up to 1 mA; at 2 mA the whole shot (tt, ss), 0.21 ns at ff | post-layout, 3 corners (information) |
| Readout: flag slots and immediate output change | correct in every case | correct in every case | post-layout, RC extraction: tt, ss 85 °C 1.14 V and ff 0 °C 1.26 V, clock held low; tt with the clock held high |
Characterization curves
65 nm CMOS · Post-layout simulation with extracted parasitics. Each caption identifies stimulus, extraction and corner coverage. Select a plot or use the arrow buttons; select its image to enlarge.
Detection of a 60-ps prompt

Detection of a 5-ns pulse

Detection threshold over corners, temperature and supply

How far the well must fall

Response time

Readout through the cell test

No false flags: disturbance against the detection level

What the sensors see on a noisy supply

Monte Carlo of the detection threshold

Static current

Flag clear from the trigger

Well bias during a long shot (information)

Trigger, detection and readout
- Before a series of shots, pulse the chip reset (low for at least 2 ns; a 0.9-ns pulse is too short at ss, 85 °C, 1.14 V): the register, the read-out flop and the capture stages go to 0. Then clock the cell-test input and read the expected ring sequence.
- Give a trigger pulse: both flags and the capture frame are cleared. No clock edge between this pulse and the shot.
- Fire the laser at least 5 ns after the trigger edge at the pad.
- Read: the output flips at once if a flag sets and stays flipped. Then clock: the clock-high slots are the register bits (a differing bit is an upset, its position gives the flop); the first clock-low slot after the first rising edge is the S2 flag, the second the classic BBICS flag; later clock-low slots read 0. If the clock was held high during the shot, the slots move by one edge.
- Every trigger pulse, also those of other experiments, clears both flags.
- For cell-test measurements, hold the chip reset low and give one trigger pulse before the first measurement; the macro output then stays 0.
- A long laser shot forward-biases the sensing wells: use a current-limited supply.
Operating limits and test precautions
Recorded limits for the deliberate laser-target structures and sensor output. The original targets and operating precautions are retained below.
| Measure | Value | Specification | Basis and operating guidance |
|---|---|---|---|
| Classic BBICS prompt threshold at the slow corner with +5 % supply | 108 fC at ss, 0 °C (1.14 and 1.26 V) and ss, 27 °C, 1.26 V | ≤ 100 fC | Reported as the corner spread of the sensor: 84 fC typical; under mismatch at 27 °C every run stays at or below 88 fC. |
| Strike to the macro output, prompt at twice the threshold | up to 0.68 ns (classic BBICS) and 0.91 ns (S2), at ss, 85 °C, 1.14 V | ≤ 0.5 ns (target) | Within the 1-ns limit accepted at sign-off. The flag latch itself is set within 0.2 ns; the output is read statically afterwards. |
| Monitored wells tied to the supply through the sensors, not directly | in operation the wells stay within about 30 mV of the supply; during a 0.5 to 1 mA, 100-ns laser shot the classic BBICS well sits 0.77 to 0.80 V below the supply for the whole shot (tt) | wells tied straight to the supply | Accepted by the project owner for these sensing wells. Lab rule: a current-limited supply, and a power cycle on a current jump. |
| Gate-oxide voltage of the struck flops under a 512-fC drain strike | up to 2.22 V for at most 0.77 ns, in the register flops only | ≤ 1.32 V | The flops are the deliberate laser targets; accepted by the project owner. The sensors and the logic stay within the limit. |
Verification scope
Recorded verification scope (with the operating limits documented in the Operation section): design rules with the latch-up checks, layout versus schematic, antenna, floating-net and single-via checks, RC and capacitance-only extraction, post-layout acceptance of both sensors at 31 corner points with Monte Carlo, and the gate-oxide voltage check. Post-layout simulation with extracted parasitics.
Thresholds are simulation-grid values for injected well currents, not measured laser-energy thresholds. Characterization plots and tables distinguish capacitance-only extraction, full RC extraction and local-mismatch Monte Carlo.
Comparison with published detectors
Published BBICS and related on-chip laser-current detectors against this work (post-layout simulation). Published values are transcribed from the supplied comparison, with the reported source location retained in each entry; a dash means the source parts we could read give no number. DOI links to the publisher.
[1] E. H. Neto, I. Ribeiro, M. Vieira, G. Wirth, F. L. Kastensmidt · 100 nm CMOS
- Venue
- IEEE Micro
- Year
- 2006
- Process
- 100 nm CMOS
- Sensor
- bulk BICS; separate sensors for the N-well and the P-well
- Detection threshold (stimulus)
- minimum detected current 257 / 217 µA (bit flip at 345 / 365 µA), double exponential 1 / 15 ps, SRAM cell
- Response
- -
- Area
- 15 % of the active area (128 SRAM cells)
- Power
- two orders of magnitude below a standard BICS
- Basis
- simulation
- DOI
- 10.1109/MM.2006.103
- Values from
- QUOTED: full text, Tables 1 and 3
[2] R. Possamai Bastos, F. Sill Torres, G. Di Natale, M.-L. Flottes, B. Rouzeyre · 32 nm (predictive model)
- Venue
- Microelectron. Reliab.
- Year
- 2012
- Process
- 32 nm (predictive model)
- Sensor
- latch-based BBICS with a sleep mode; NMOS and PMOS bulks
- Detection threshold (stimulus)
- designed for a 50-ps current pulse whose transient reaches 50 % of the supply
- Response
- hundreds of picoseconds
- Area
- about 25 % with the sleep mode (area and power)
- Power
- +15 % power
- Basis
- simulation
- DOI
- 10.1016/j.microrel.2012.06.149
- Values from
- QUOTED: abstract; full text, Fig. 3 and section 5
[3] J.-M. Dutertre, R. Possamai Bastos, O. Potin, M.-L. Flottes, B. Rouzeyre, G. Di Natale · 65 nm CMOS
- Venue
- Microelectron. Reliab.
- Year
- 2013
- Process
- 65 nm CMOS
- Sensor
- latch BBICS tuned by latch asymmetry and delayed access; N-well and substrate sensors
- Detection threshold (stimulus)
- N-well sensor: 126.6 µA / 21.5 fC (TT, 27 °C), 67.3 µA / 11.6 fC (FF, 80 °C) to 148.7 µA / 25.3 fC (FS, 0 °C); pulse 8.2 ps rise, 124 ps width, 330 ps fall; 2 × 10 inverters
- Response
- -
- Area
- 12.1 µm² (N-well sensor), 11.3 µm² (substrate sensor)
- Power
- -
- Basis
- simulation with cell parasitics
- DOI
- 10.1016/j.microrel.2013.07.069
- Values from
- QUOTED: full text, Tables 1 and 3
[4] J.-M. Dutertre et al. · 65 nm CMOS
- Venue
- Microelectron. Reliab.
- Year
- 2014
- Process
- 65 nm CMOS
- Sensor
- one BBICS for NMOS and PMOS (14 transistors)
- Detection threshold (stimulus)
- PMOS strikes: 45 to 134 µA for 40 to 200 inverters; pulse about 50 ps rise, 150 ps fall
- Response
- -
- Area
- 22.6 µm² (5.4 % of a 200-inverter chain)
- Power
- -
- Basis
- simulation after RC extraction
- DOI
- 10.1016/j.microrel.2014.07.151
- Values from
- QUOTED: full text, Table 2
[5] C. Champeix, N. Borrel, J.-M. Dutertre, B. Robisson, M. Lisart, A. Sarafianos · 90 nm CMOS
- Venue
- IOLTS
- Year
- 2015
- Process
- 90 nm CMOS
- Sensor
- one BBICS for NMOS and PMOS; half of the well taps through the sensor
- Detection threshold (stimulus)
- -; backside 1064-nm laser, 50 to 200-ns pulses, about 1-µm spot
- Response
- a few nanoseconds
- Area
- -
- Power
- -
- Basis
- silicon, laser
- DOI
- 10.1109/IOLTS.2015.7229849
- Values from
- QUOTED: full text, section IV
[6] C. Champeix, J.-M. Dutertre, V. Pouget, B. Robisson, M. Lisart, N. Borrel, A. Sarafianos · 40 nm CMOS
- Venue
- RADECS
- Year
- 2016
- Process
- 40 nm CMOS
- Sensor
- double-access BBICS, NMOS and PMOS
- Detection threshold (stimulus)
- 0.1 nJ laser energy (bench setting) against 0.5 nJ for a flip-flop upset, 1030 nm, 30-ps pulses, about 1-µm spot; simulation: 49 µA for a 30.61-ps pulse
- Response
- -
- Area
- -
- Power
- -
- Basis
- silicon (laser) and simulation
- DOI
- 10.1109/RADECS.2016.8093172
- Values from
- QUOTED: full text, sections III and IV
[7] K. Matsuda et al. · 0.18 µm CMOS
- Venue
- IEEE JSSC
- Year
- 2018
- Process
- 0.18 µm CMOS
- Sensor
- distributed bulk-current sensor with a secure flush eraser
- Detection threshold (stimulus)
- 100 % attack detection coverage
- Response
- eraser within nanoseconds
- Area
- 286 F² per cell; +28 % layout area
- Power
- -
- Basis
- silicon
- DOI
- 10.1109/JSSC.2018.2869142
- Values from
- QUOTED: abstract
[8] K. Matsuda et al. · 0.18 µm CMOS
- Venue
- Jpn. J. Appl. Phys.
- Year
- 2020
- Process
- 0.18 µm CMOS
- Sensor
- distributed bulk-current sensors, latch back end, tunable threshold
- Detection threshold (stimulus)
- alarm above 0.3 nJ (970 nm, 200-ns pulses, 20-µm spot), against 4.26 nJ for a fault; simulation: sensitivity tunable within 20 µA and 60 µA
- Response
- five sensor outputs scanned in 60 ns (simulation)
- Area
- front end 286 F² per cell, back end 850 F² per cell; +23 %
- Power
- no standby power
- Basis
- silicon (laser) and simulation
- DOI
- 10.7567/1347-4065/ab65d3
- Values from
- QUOTED: full text, sections 3 and 4, Table I
[9] M. Kharbouche-Harrari et al. · 28 nm FD-SOI with STT-MRAM
- Venue
- IOLTS
- Year
- 2019
- Process
- 28 nm FD-SOI with STT-MRAM
- Sensor
- BBICS on both wells plus a magnetic junction for heating attacks
- Detection threshold (stimulus)
- -
- Response
- -
- Area
- +6.4 gate equivalents over a pure BBICS
- Power
- -
- Basis
- simulation, Monte Carlo
- DOI
- 10.1109/IOLTS.2019.8854374
- Values from
- QUOTED: full text
[10] M. Andjelkovic et al. · 130 nm CMOS
- Venue
- Microelectron. Reliab.
- Year
- 2022
- Process
- 130 nm CMOS
- Sensor
- BBICS with a pulse stretcher; N-well (PMOS bulks)
- Detection threshold (stimulus)
- threshold LET about 1.7 MeV·cm²/mg for ten monitored inverters
- Response
- output pulse 620 to 800 ps (stretched)
- Area
- -
- Power
- -
- Basis
- simulation
- DOI
- 10.1016/j.microrel.2022.114726
- Values from
- QUOTED: abstract and full text, section 5
[11] D. Batabyal, S. K. Singh, R. K. Mishra, A. Grover · 65 nm CMOS
- Venue
- VLSID
- Year
- 2023
- Process
- 65 nm CMOS
- Sensor
- sense-amplifier BBICS, substrate current sampled in turns
- Detection threshold (stimulus)
- 20 µA sustained for 10 ns
- Response
- -
- Area
- -
- Power
- leakage and power below 0.1 % of the SoC
- Basis
- simulation
- DOI
- 10.1109/VLSID57277.2023.00028
- Values from
- QUOTED: abstract
[12] A. Guichaoua, S. Lesne, J.-B. Rigaud, J.-M. Dutertre · 65 nm CMOS
- Venue
- CASCADE
- Year
- 2026
- Process
- 65 nm CMOS
- Sensor
- BBICS watching dual-well and triple-well targets
- Detection threshold (stimulus)
- below the fault sensitivity (no number in the abstract); detection radius up to about 100 µm; picosecond laser
- Response
- -
- Area
- -
- Power
- -
- Basis
- silicon, laser
- DOI
- 10.1007/978-3-032-25149-7_19
- Values from
- QUOTED: abstract
This work: classic BBICS · 65 nm CMOS
- Venue
- -
- Year
- 2026
- Process
- 65 nm CMOS
- Sensor
- access PMOS as resistor, sensing PMOS on the well, latch with weak hold; N-well of 8 flops
- Detection threshold (stimulus)
- 84 fC typical (56–108 fC), 60-ps prompt into the well junction; 25 µA (20–30 µA), 5-ns pulse
- Response
- 92 ps to the flag, 0.48 ns to the output (twice the threshold, typical)
- Area
- 37.1 µm² (sensor, latch, flag buffers)
- Power
- no bias current
- Basis
- post-layout simulation
- DOI
- -
- Values from
- this page
This work: S2 · 65 nm CMOS
- Venue
- -
- Year
- 2026
- Process
- 65 nm CMOS
- Sensor
- AC-coupled, pre-biased current comparator; 2 kΩ access; detect clamp; N-well of 8 flops
- Detection threshold (stimulus)
- 80 fC typical (64–100 fC), 60-ps prompt; 50 µA (40–70 µA), 5-ns pulse
- Response
- 156 ps to the flag, 0.65 ns to the output
- Area
- 266 µm² with its 50-fF coupling capacitor
- Power
- bias inside the macro's 1.08 µA static current
- Basis
- post-layout simulation
- DOI
- -
- Values from
- this page
Thresholds are not directly comparable: the rows differ in where the current is injected (a drain in the monitored logic, the well junction, or a laser spot), in its shape and length, in the monitored circuit and in the basis (simulation or silicon); laser energies are bench settings, not the energy reaching the junction. The thresholds of this work are charges and currents injected at the N-well / substrate junction of the struck well segment.
Further work on bulk built-in current sensors, without numbers in the parts we could read: G. Wirth and C. Fayomi, ISSOC 2007 (doi:10.1109/ISSOC.2007.4427422), and G. Wirth, Microelectron. Reliab. 2008 (doi:10.1016/j.microrel.2008.01.002), on SET detection; A. Simionovski and G. I. Wirth, LASCAS 2012 (doi:10.1109/LASCAS.2012.6180338), a dynamic storage cell; R. Possamai Bastos et al., VARI 2014 (doi:10.1109/VARI.2014.6957089) and Microelectron. J. 2018 (doi:10.1016/j.mejo.2017.11.006), comparisons of BBICS architectures; N. Borrel et al., DFTS 2015 (doi:10.1109/DFT.2015.7315141), triple-well effects; R. Possamai Bastos et al., IEEE Trans. Nucl. Sci. 2020 (doi:10.1109/TNS.2020.2975923), a BBICS on a 65-nm test chip under neutrons and laser; R. Viera, N. Backert and J.-M. Dutertre, ISQED 2026 (doi:10.1109/ISQED69900.2026.11534676), a power-off laser attack against BBICS.
Post-layout simulation with extracted parasitics · Stimulus and corner coverage identified with each result.